Sign In | Join Free | My burrillandco.com
Home > LED Canopy Lights >

UL DLC Listed Gas Station Led Canopy Lights IP65 With Smart Fin Shape Heat Sink

    Buy cheap UL DLC Listed Gas Station Led Canopy Lights IP65 With Smart Fin Shape Heat Sink from wholesalers
     
    Buy cheap UL DLC Listed Gas Station Led Canopy Lights IP65 With Smart Fin Shape Heat Sink from wholesalers
    • Buy cheap UL DLC Listed Gas Station Led Canopy Lights IP65 With Smart Fin Shape Heat Sink from wholesalers
    • Buy cheap UL DLC Listed Gas Station Led Canopy Lights IP65 With Smart Fin Shape Heat Sink from wholesalers
    • Buy cheap UL DLC Listed Gas Station Led Canopy Lights IP65 With Smart Fin Shape Heat Sink from wholesalers

    UL DLC Listed Gas Station Led Canopy Lights IP65 With Smart Fin Shape Heat Sink

    Ask Lasest Price
    Brand Name : ATA
    Model Number : ATA-CP100W
    Certification : CE, RoHS, SAA, C-Tick, RCM, CB, FCC, PSE, CCC, ETL, TUV-GS, TUV-mark, VDE, ERP, UL, cUL, DLC
    Price : US $24-66/ Piece
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram, Paypal, Cash
    Supply Ability : 300, 000/Pieces/Month
    Delivery Time : Samples 3-5 working days, normal orders 7-10 working days
    • Product Details
    • Company Profile

    UL DLC Listed Gas Station Led Canopy Lights IP65 With Smart Fin Shape Heat Sink

    UL DLC Listed IP65 LED Canopy Lights 30w 45w 60w 75w 100w outdoor led parking garage light


    LED Canopy Light owns the smallest size in the market, 265*265*95mm, it is the most cost effective led canopy light in the market.

    The heavy-duty die cast aluminum heatsink can provide strong resistance to corrosion and weathering, so that the led canopy can

    be used in wet location.There are 3 ways for easy installation, mount with J-box or 1/2" conduit, pendant install with 3/4" conduit


    Product information:
    Input Voltage: AC100-277V/347 50/60Hz
    Power: 30w 45w 60w 75w 100w
    CCT: WW(3000K), NW(4000K), DW(5000K), CW(6000K)
    Light Source: lumileds 3030SMD LED
    Certification: UL DLC CE, RoHS
    Description: LED canopy lights with smart fin shape heat sink, better heat dissipation and longer life span, good quality with the use of MeanWell driver and Lumileds chips.

    Item No.Specification
    PowerInput VoltageLumious Flux(lm)MH/HPS EquivalentProduct DimensionLuminous Efficiency
    ATA-CP30W30WAC100~277V/347V1450±5%100-175W265*265*95mm120LM/W
    ATA-CP45W45WAC100~277V/347V2400±5%200W265*265*95mm
    ATA-CP60W60WAC100~277V/347V3300±5%250W265*265*95mm
    ATA-CP75W75WAC100~277V/347V5400±5%300W265*265*95mm
    ATA-CP100W100WAC100~277V/347V1080±5%400W265*265*95mm

    Installation

    1. Surface Mounted with J-box
    1.1Loosen the screw on side of the light, removing the bracket from Canopy light by pulling it out slightly, just leaving the ring on bracket.
    1.2 Fix the bracket on J-box, and put the wire through the central hole for wiring.
    1.3. Attach the Canopy light with bracket by putting the ring on clips again. Connect the Black wire for Line, White for Neutral, Yellow Green for Ground.
    1.4.Slide the Canopy lights into bracket, and secure the screw on side of the light to prevent the light from sliding out from the bracket. Installation done.

    2. Pendent with 3/4 inch Conduit
    2.1. Loosen the screw on side of the light, removing the bracket from Canopy light by pulling it slightly out, just leaving the ring on bracket. ( See the Step 1 above)
    2.2. Connect the wires threaded from conduit and Canopy, Black wire for Line, White for Neutral, Yellow Green for Ground.
    2.3. Screw the Conduit into the hole on top of Canopy light. Installation done.
    3. Surface mount

    3.1. Remove the lens and metal plate by unscrewing the screws.
    3.2 2.Drill 4 holes on edge of fixture and fix it on the ceiling with using appropriate screws. Cut off the wires through from 3/4'' hole and plug the hole with provided Plug.
    3.3. Remove 1/2" plug from direction you intend to feed conduit.
    3.4. Disconnect the wires came from 3/4'' hole and connect the wires came from 1/2'' conduit with power supply . (White for Neutral, Black for Line, Yellow Green/Green for Ground)
    3.5. Replace the metal plate and the lens, make sure no wires are pinched when replacing parts.



    Application:
    Factories, Yards, Gas station, Gymnasiums, Wineries, Schools/government buildings, Exhibition, Hospitals, Applications in Storage Areas, Garages, Canopies, Warehouses, Hotel Canopies, Entry Ways, Security Lighting etc.


    User Manual
    Switch off power of the mains supply or respectively of the connection lead before doing any works.
    Assembly must not damage or destroy conducting paths.
    Make sure that the product is mounted on a stable, even and tilt-fixed background.
    The complete installation must be done by an electrical expert who is familiar with the valid directives.

    Quaity Control
    Stability TEST: make sure 100% of the lamps be aging test at least 48hours
    Lighting TEST: make sure 100% of the lamps be lighted before packing
    Drop TEST: make sure every single light have been well protected by box

    Contact
    Peony Jin
    Mobile: 0086-180 0253 2737
    Please feel free to send us your inquiry, We are at your service any time!

    Quality UL DLC Listed Gas Station Led Canopy Lights IP65 With Smart Fin Shape Heat Sink for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen ATA Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)